creativecommons.org
Water heaters from this company have proven themselves quite well in the market for such devices. That is why we decided to prepare an article with instructions for the Vector geyser, so that everyone can find information about the maintenance of the system.
The content of the article
- Geyser device Vector
- How to turn on the geyser Vector
- Geyser Vector - instruction manual
Geyser device Vector
Any model of the company's gas burner has the following components:
- The main component, without which the operation of the device is impossible, is a copper heating element. This is a large number of small tubes through which cold water is supplied. Under the influence of a gas burner on the surface of the pipe, the system heats up all the liquid and outputs it to the mixer.
- Columns Vector have electric ignition. That is why working with such equipment is many times safer than open fire: the latter always has an active flame, and it does not stop.
- The gas supply unit starts working after opening a special valve. It is a self-regulating system that does not work without water flow. This is the safety of the gas burner - replace the valve in time so that it works fully.
- The mixture for the gas burner is supplied in a special chamber. It is connected to a steel pipe outlet. Inside there is a sensor that turns off the system in the absence of water.
- Another thermostat is designed to protect the device from overheating. It is installed at the point of the highest temperature indicator - in the center of the heat exchanger. When the temperature reaches 80 Celsius, the device automatically turns off.
How to turn on the geyser Vector
The first stage is the installation of batteries for electric ignition. To do this, open the battery compartment and put the batteries, according to the desired polarity.
Then we open the tap for cold water and gas supply, as well as the nearest mixer for hot water. Under the spark from the batteries, the burner starts to work. If nothing happened, actively open/close each faucet several times.
If the burner ignites properly, turn the steam control valve to the right. This will activate the Vector gas heater system and provide hot water.
Geyser Vector - instruction manual
The device can and should be installed in any non-residential premises where there is heating. The volume of the room must be at least 8 cubic meters. Definitely there must be ventilation or a place for ventilation, since the burner recycles oxygen to work. In addition, a separate chimney is required.
The installation itself is carried out by specialists of the gas service and only with the permission of the gas workers, otherwise they may be forced to remove the apparatus and forbid it to be used.
The hinged system is installed exclusively on a wall upholstered with galvanized metal, or from fireclay bricks (not collapsing at high temperatures.
Water should be connected to the heater through a separate filter. At the first start, a little cloudy water will flow, but this is not critical - all waste is drained and the system restarts. After the clean liquid has gone, you can begin to actively use the geyser.