Damage to the water heater is always unpleasant. However, do not be upset and think about buying a new device - perhaps the malfunction is easily fixed, especially if it is a leak.
Why did the water heater flow
The content of the article
- Why did the water heater flow
- Why does the water heater need a safety valve?
- What to do if a water heater flows
- Prevention so that the water heater does not leak in the future
If a water heater has flowed, first of all it is necessary to localize the problem. There are 3 options:
- Poorly assembled water supply;
- The check valve leaks;
- Flowing from under the tank itself.
If the leak occurs at the junction of the sanitary fittings, try to tighten the problematic joints more tightly with a pair of adjustable wrenches. If this does not help, you need to disassemble the leaking section of the pipeline, and reassemble it, checking the quality of the fitting, not forgetting to use the appropriate sealing material.
Why does the water heater need a safety valve?
Water heater flowed, what should I do? The check valve assembly always uses a non-return valve. This is for two main purposes. Firstly, it prevents the reverse flow of heated water in the direction of the cold riser.
Secondly, the valve protects the tank by relieving excess pressure generated due to expansion of the heated fluid or coming from the line during a period of lack of analysis.
The check valve is a T-shaped fitting that allows water to pass in one direction (from the riser to the drive). If the pressure exceeds the maximum permissible for the heating device (as a rule, it is 6 atmospheres), the spring inside the valve is compressed, opening a drainage hole.
Why is water dripping from the safety valve of the water heater? If the water heater was assembled efficiently, when filling the tank with water, the check valve did not let water through, but after the start heating and during operation of the tank, water gradually oozed through it - this is a standard situation, there is no breakdown in this not.
Moreover, in houses with centralized water supply, the flow can increase significantly at night, when water intake is significantly reduced, and the pressure in the system, accordingly, increases. To combat overpressure in the system, it is possible to install a gearbox with a pressure gauge at the inlet of the device to monitor and adjust this parameter during operation.
Attention! If the non-return valve does not discharge water together due to excess pressure, it is most likely clogged and urgent need to be cleaned or replaced, otherwise it may suffer from this heater.
Typically, water flowing from a valve through a drainage tube is collected in a storage tank or lowered into a sewer. The volume of liquid discharged per day is 1.5-3% of the size of the storage tank.
If the flow is more intense, the spring inside the fuse may be damaged, the inner gasket has moved away, or it is clogged. In this case, it must be dismantled, disassembled, cleaned and reassembled. If this does not help, replace the valve fitting with a working one.
What to do if a water heater flows
The most unpleasant if the leak is connected with the boiler itself. If a leak is detected directly from the water heater, immediately turn off the device and shut off the water. After that, you need to remove the outer cover of the device and inspect the leak.
There are two main types of malfunction: either the tank itself burst, and then the entire unit really needs to be replaced, or because the valve that has been exhausted due to some reason, due to excessive internal pressure, has squeezed out the drive gasket in the mounting area TENA.
In this case, you can try to replace this gasket yourself or call the wizard. It is also necessary to check the operation of the valve fuse or replace it.
Prevention so that the water heater does not leak in the future
To avoid such problems, it is necessary to adhere to simple rules during installation and operation:
- High-quality docking of sanitary units using gaskets;
- Connect the device to the water supply system in the correct scheme using a check valve and a reduction gear, as well as a drainage system;
- To control the temperature of heating the water in the tank, do not bring it to the maximum level;
- Turn off the heater if it is not intended to be used for a long time;
You should also use the device in accordance with the operating instructions, carry out routine maintenance.